31 / 523568 / BIPCyl8 Error description INJECT. PERIOD ZYL.8 Begin of injection of cylinder 8: the ECU can not identify the magnet valve or the injection pump with the measured value of current drain at the begin of the injection
Error codes DEUTZ-Errorcode: 31 BlinkCode (short-long-short): 5 - 3 - 8 SPN: 523568
Related Contents:
Deutz SerDia 4.0
Deutz DECOM
possible FMI: 2: data stream is defective 2: data stream is defective 2: data stream is defective 2: data stream is defective
Error detection Error lamp shows permanent light. Entry in errormemory.
Possible reason for error Value outside target range or missing (cylinder 8), magnet valve or injection pump defective
Take actions for error repair Check magnetic valve or injection pump and if necessary change them other error properties
System reaction: No function at the moment/ Allocation check cylinder! Behaviour error lamp: permanent light Selfhealing: yes Signal Priority: 3