How to repair Deutz EMR3 engine controller fault 37 / 111 / CLSCDSysReac
37 / 111 / CLSCDSysReac Error description ENG COOLANT LEVEL Coolant level: the coolant level calculated by ECU is underneath the allowed minimum Whats You Need?
Possible FMI: 1: data valid, but below normal working area 1: data valid, but below normal working area 12. Errormode not identifiable 12. Errormode not identifiable
Errordetection Errorlamp shows permanent light oder blinking. Entry in errormemory.
Possible reason for error Outside target range with system reaction, cooling system untight, sensor defective, onnection cable demaged
Take actions for error repair Check coolant level, check cabling, inspect cooling system and if necessary repair it, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Other error properties System reaction: Advice: CLSCD_stSysReacReq Behaviour error lamp: permanent light oder blinking Selfhealing: no Signal Priority: 3 Measurement @ errortime: actual value